DWBP R&T Oceana R&T R&T Lab Standards IAPMO ES R&T Lab
Skip navigation links
Why Choose IAPMO?
Services
About Us
Industry Links
Contact Us
FAQs
Skip navigation links
Accreditations
Lab Capabilities
Video
Test Kits
Testing Flow Chart
Lab Capabilities 

IAPMO R & T LAB
5001 E. PHILADELPHIA STREET
ONTARIO, CA 91761
United States
Contact: KEN WIJAYA

Phone: 909-472-4135
Fax: 909-472-4177
   Lab #: 0000055
Expires: 4/30/2008
Number of Employees: 13

Tests to Standards:
APPLIANCES:
AHAM 2PR, AHAM DW-1 (Section 6 & 7 ONLY), ASME A112.19.7M (CSA, CAN/CSA-B45S1), ASSE 1006, ASSE 1008, ASSE 1023 (less electrical), IAPMO IGC 115, IAPMO IGC 226 (except Section 4.7), IAPMO PS 88, IAPMO PS 92, IAPMO PS 119

BACKFLOW PREVENTERS:
ASME A112.18.3, ASME 12.1,2M, ASSE 1012 (CSA,CAN/CSA-B64.8),1013 , 1021, 1024 (CSA, CAN/CSA-B64.3), 1032,1035 (CSA,CAN/CSA-B64.7), 1037, ASSE 1015, 1052, 1055, IAPMO PS 23,31,38, IAPMO PS 45, IAPMO TSC 8, 21, IAPMO IGC 163

BALLCOCKS/FLUSHOMETERS:
ASME A112.19.5 (CSA B125.3), ASSE 1001 (CSA, CAN/CSA-B64.0;B64.1), 1002, , 1037, ASME A112.19.10, IAPMO PS 50,67,69,78, IGC 118, 162

EARTHQUAKE SHUTOFF\EXCESS VALVE:
IGC 175

ELECTRICAL:
IAPMO IGC 140

FUEL GAS ITEMS
ASME B16.33 (except 3.4.3 & 3.4.4), IAS LC-1 (CSA 6.26A)

METAL FIXTURES:
ASME A112.6.1, ASME A112.6.4, ASME A112.6.7, ASME A112.19.1M (CSA, B45.1), ASME A112.19.3M (CSA, B45.4) ,ASME A112.19.4M (CSA, B45.3), IAPMO IGC 217, IAPMO PS 41 (except section 8.4.1 & 8.4.2), PS 54 (except section 7.2), PS 58, PS 62, PS 117(except 4.2, 4.3), IGC 82, METAL ANALYSIS, IGC 193, 194, 195(except 4.1 and 4.2), IGC 217, IGC 227, IGC 235 (except Sec. 5.5)

METAL PIPE/FITTINGS:
ASME A112.3.1 (except 4.4.3 rubber), ASME A112.6.3, ASME A112.18.2 (except cell class),ASME A112.21.2M (except section 6) , ASME A112.21.3M, ASME A112.36.2M (except section 6 & 7.1.1), ASME B16.18, ASME B16.22a, ASSE 1061, ASTM A 888 (CSA, CAN/CSA-B70-M91), ASTM A 74(CSA, CAN/CSA-B70-M91), ASTM C1173, ASTM C 1277,ASTM C 1540, IGC 100, IGC 137, IGC 146(except 4.1), IGC 188(except 4.1), IGC 198, IGC 201, IGC 208, IGC 215, IGC 218, IGC 233 (except Section 4.5), IAPMO PS-2, 4, 7, 9, PS-14-89, 14-99a, PS 16 (except cell clasification), 44 (except 6.1), PS 53 (except 4.1, 4.2 and 4.5), PS 55 (except section 4.3, 4.4, 4.5), 79, 76, 97,PS 109 (except section 6) CISPI 301, CISPI 310, SAE J1670, METAL ANALYSIS

MFG. HOUSING/RV COMPONENTS:
IGC 132, IGC 209(less material) PS 42, TSC-1-97, 1-98x, 11, 19, 20, 21, 24, 26 (except section 3.2.3), 34, TSC 2, TSC 4,TSC 9 (except section 11.5 & 11.6) TSC 12, TSC 13, TSC 14, TSC 15, TSC 22, TSC 23, TSC 25, TSC 27, TSC 28, TSC 30, TSC 33

NON METALLIC PIPE FITTINGS:
ASME A112.18.6, ASME A112.21.2M, IAPMO PS 42, IAPMO PS 57 IAPMO PS-69, (except material), IAPMO PS 94, IAPMO PS 95 IAPMO TSC 11, 19, 26, IGC 67,IGC 81(less material), IGC 87, 117 (4.1), IGC 211, ASTM F-409 (except section 5)

NON VITREOUS CHINA FIXTURES:
CSA MSE-41

PLASTIC FIXTURES:
ANSI Z124.1.2,.3,.4,.5,.6,.7, (CSA, B45.5-94), 8,.9, ASME A112.19 .2,.3 (CSA, B45.4) 5,.6,.7(CAN/CSA-B45S1), 8.,.9 M (CSA,B45S1), ASME A112.19.7M (CAN/CSA-B45S1),ASTM F 462, IGC 138, 141, 142, 154, 155, 171 (except section 7.2), 172, 197(except 4.12, 4.13, 5.1), 200, 227, IAPMO PS-70, 84 (except section 5.2), 93

PLASTIC PIPE/FITTINGS:
ASME A112.18.2, ASSE 1050, ASSE 1051, ASTM D 2661, ASTM D 2665 (except section 5.1 cell classification), ASTM F628 (except section 5.1 cell classification and section 6.3), ASTM F877 (for fitting only), ASTM F1807, ASTM F1960 (except 6.1), ASTM F1974, ASTM F2158, CSA B137 (except Section 4.7), CSA B181.1 (except Section 3.1 Cell Classification and 4.4 carbon black), B181.2 (except section 3.1 Cell Classification), IAPMO IGC 109, IGC 111, IGC 122, IGC 161, IGC 165 (except section 3.1.1, 3.1.2), IGC 192 (except 6.0), IGC 223 (except Sections 4.2, 4.3, 4.5 and 6.2), IGC 224, IGC 225, IGC 228 (except Sections 4.2.1, 4.2.5, and 4.8), IGC 229 (except Section 4.3),IGC 236, IAPMO PS 25, PS 34 (less cell classification), PS 43, PS 64 (except Sections 4.1.3 and 5.3), PS 69 (except section 5.1, 5.2), PS 90 (except section 4.1.1), PS 98, PS 102, PS 104, PS 110 (except 4.1 & 5.3), PS 111 (except section 4.1, 4.4 & 5.3), IAPMO TSC 7

POOL/SPA COMPONENTS/FITTINGS:
ASME A112.19.7M (CAN/CSA-B45S1), ASME A112.19.8M, IAPMO PS-33, IAPMO SPS-4
SEPTIC SYSTEMS:
IAPMO IGC 164, IGC 167 (except section 4.4 & 4.5), IGC 180 (witness test only), IGC 199, IGC 231 (witness testing only), IAPMO PS 52 (except section 4.1 thru 4.4), PS 59 ( except section 3.1 materials), PS 60 (except section 4.1 thru 4.4), PS 80 (except section 4 & 5), IAPMO ANSI Z1000-2007, IAPMO Z1001-2007

TOXICITY TESTING:
NSF 61

VACUUM BREAKERS:
ASSE 1001 (CSA, CAN/CSA-B64.0;B64.1.1),1002, 1011(CSA, CAN/CSA-B64.2.1, B64.2.2, B64.1.2), 1019, 1020, 1035(CSA,CAN/CSA-B64.7), ASME A112.19.1M (CSA, B45.2), CSA B356

VALVES/FAUCETS:
ASME A112.14.1M, A112.18.1 (CSA B125.1), ASSE 1003, 1014, 1016,1017,1018,1019,1025,1035 (CSA,CAN/CSA-B64.7),1044, 1057(except section 4.4.1), 1062, 1066, 1069,1070, CSA B356, IAPMO IGC PR4-8, ICC/ANSI A117.1, IGC 115, IGC 124, IGC 145, IGC 128, IGC 151, IGC 152, IGC 157, 163, 170 (except 4.1 & 4.2), IGC 203, 204, 206, 216, 230, 232 (except Section 4.1), 234, PS-45, 49, 72, MSS 70, MSS 71, MSS 72, IAPMO PS 71 (except section 4.4 & 5.3), PS 86, PS 104, PS 112 (except section 3.1) METAL ANALYSIS, PS 115 (except 5.6), PS 116 (except 4.4),


VITREOUS/NON VITREOUS CHINA FIXTURES:
ASME A112.19.2 (CSA B45-1), ASME A112.19.3M (CSA, B45.4), .9M, IGC 156, PS 58, PS 99, ICC/ANSI A117.1, ASME A112.19.12, ASME A112.18.2 (CSA B125.2)

WATER CLOSETS:
ASME A112.4.2, ASME A112.6.2, ASME A112.19.14, IAPMO IGC 45, IGC 82, IGC 150, IGC 207, IGC 222 (except Sec. 4.6), IAPMO PS 61, PS 77, PS 93, IAPMO TSC 1, TSC 24, TSC 34, LADWP SPS, UNAR 2006

WATER HEATERS:
IAPMO IGC 86, SRCC 100